350W 8-ZONE IP POWER AMPLIFIER

T-77350Z

350W 8-Zone IP Network Power Amplifier

8 x Independent 100V Zones • 350W Total Power • LCD Display • Infrared Remote • EMC Priority • Fire Alarm Linkage

8 ZONES • 350W • 100V • EMC • FIRE LINKAGE • HIGH POWER
T-77350Z 350W 8-Zone IP Network Power Amplifier
T-77350Z Front Panel
T-77350Z Rear Panel - Zone Outputs
T-77350Z LCD Display
350W 8-ZONE AMPLIFIER

IP Network Power Amplifier

T-77350Z

8 x 100V Zones
350W Total Power
LCD Display
IR Remote
Fire Alarm Linkage
EMC Priority
MIC/AUX Input
Intelligent Power

High-power 8-zone amplification for demanding applications. The T-77350Z delivers 350W total power across eight independent 100V zones, combining multi-zone routing with built-in amplification in a single 2U chassis. Ideal for hospitals, large schools, conference centers, and other venues requiring substantial power per zone.

Technical Specifications – T-77350Z

350W 8-ZONE MODEL Part of the T-7700Z series (240W, 350W, 500W)
Model NumberT-77350Z
Product Type8-Zone IP Network Power Amplifier
Form Factor2U, 19" Rack Mount
Total Output Power350W (shared across 8 zones)
Zone Outputs8 x Independent 100V Constant Voltage
Zone Power AllocationDynamic / Programmable (per-zone limits configurable)
DisplayLCD (Character/Graphic)
Network10/100Mbps Ethernet (RJ45)
Audio ProtocolsTCP/IP, UDP, HTTP, RTP, RTSP
Audio CodecsMP3, WAV, PCM
Frequency Response80Hz – 16kHz (±3dB)
THD+N< 0.5% (1kHz, rated power)
S/N Ratio> 85dB
Input SensitivityMIC: 5mV, AUX: 300mV
Remote ControlInfrared (included)
Priority ControlEMC input (contact closure), highest priority
Fire Alarm LinkageDry contact input, programmable zone activation
Intelligent Power ManagementAuto standby per zone, configurable timeout
CoolingVariable speed fan, front-to-rear airflow
ProtectionOverload, short circuit, over-temperature, DC fault
Power SupplyAC 100-240V, 50/60Hz, internal
Dimensions (WxDxH)483 x 340 x 88 mm (2U)
Weight14.8 kg
Operating Temperature0°C – 40°C
Humidity10% – 90% non-condensing
CertificationsCE, FCC, RoHS
Zone Power Allocation

The T-77350Z has a total power budget of 350W shared across eight zones. Power can be allocated dynamically – for example, Zone 1 can use 150W for a large hall while Zones 2-8 share the remaining 200W, or all zones can be limited to 43W each. Per-zone power limits are configurable via software to prevent overload.

Product Overview – T-77350Z

The T-77350Z is a high-power 8-zone IP network power amplifier that combines multi-zone routing with 350W of built-in amplification. It receives network audio, routes it to any of eight independent 100V zones, and amplifies it internally – all in a single 2U rack chassis. This is the mid-power option in the T-7700Z series, offering 350W for demanding multi-zone applications.

Complete Zone Amplification: Each of the eight zones is a dedicated 100V constant voltage output with its own amplifier stage. Zones can be activated individually, in groups, or all simultaneously. No external amplifiers are needed, reducing installation complexity and cost.

350W Power for Larger Zones: With 350W total power, the T-77350Z can handle demanding applications such as:

  • Hospitals with large public areas and multiple nurse call zones
  • Large schools with gymnasiums, auditoriums, and classroom wings
  • Conference centers with multiple meeting rooms
  • Shopping malls with anchor stores and common areas
  • Industrial facilities with large zones

Flexible Power Distribution: A hospital might allocate 100W to a large cafeteria, 80W to a waiting area, and 30W each to five clinic zones (100+80+150=330W). Power limits are software-configurable per zone to match specific requirements.

Fire Alarm Integration: Dedicated fire alarm linkage inputs allow emergency messages to override any zone with highest priority. Programmable evacuation patterns comply with international life safety standards.

8 Independent 100V Zones

Individual zone control with built-in 350W amplification. No external amplifiers needed. Per-zone volume and source routing.

Fire Alarm Linkage

Direct interface with conventional fire panels. Programmable zone activation patterns for phased evacuation.

Intelligent Power Management

Per-zone auto standby reduces energy consumption. Zones power up only when audio is present, with configurable timeout.

Infrared Remote

Full-function IR remote for zone selection, volume, source switching, and emergency override. Range: 8 meters.

Typical Applications
  • Hospitals: Large cafeteria (100W), waiting areas (80W), multiple clinic zones (30W each)
  • Large schools: Gymnasium (120W), auditorium (100W), 6 classroom wings (20W each)
  • Conference centers: 8 meeting rooms with varying power requirements
  • Shopping malls: Anchor stores (80W each), common areas (40W each)
  • Hotels: Ballroom (120W), restaurants (60W), conference rooms (30W each)

Zone Matrix & I/O – T-77350Z

8x 100V Zones Independent
350W Total Shared
LCD Display Status
Fire Linkage 8 zones
MIC Input Front/rear
AUX Input RCA
IR Remote Included
EMC Priority Override
Zone Configuration & Power Allocation
Zone Output Type Max Power (Configurable) Example Allocation
Zone 1 100V Constant Voltage 0-350W Gymnasium: 120W
Zone 2 100V Constant Voltage 0-350W Auditorium: 100W
Zones 3-8 100V Constant Voltage 0-350W each (total ≤350W) Classrooms: 6×20W = 120W

Power limits are set via T-7700RP software. The amplifier automatically manages total power to prevent overload. Example total: 120W + 100W + 120W = 340W (within 350W budget).

Front Panel Controls & Display
  • LCD display: Shows zone status, power allocation, IP address, volume, source
  • Zone select buttons: 8 backlit buttons for manual zone activation and status
  • Master volume: Rotary encoder with push-button mute
  • Source select: Network, AUX, MIC
  • MIC input: Front-panel 6.35mm with gain control
  • IR receiver: Front panel, 8m range
  • Power LED: Blue - active, Amber - standby
  • Alarm LED: Red flashing during fire linkage
Rear Panel I/O
  • Zone 1-8 outputs: Screw terminals, 100V constant voltage
  • Fire input: Screw terminal, dry contact (programmable zone activation)
  • EMC input: Screw terminal, priority override
  • COM/NC/NO relay: Fault output, 30V/1A
  • AUX input: RCA, 300mV sensitivity
  • MIC input: Rear 6.35mm, 5mV sensitivity
  • Ethernet: RJ45, 10/100, Link/Act LED
  • AC inlet: IEC C14, 100-240V
Fire Alarm Linkage Programming
Trigger Programmable Actions Example
Fire Input 1 Activate zones 1,2,3 at 100% volume, play emergency message Zone 1-3 evacuation
Fire Input 2 Activate zones 4,5,6 at 100% volume, play alternate message Zone 4-6 evacuation
EMC Input Activate ALL zones, highest priority, overrides fire inputs Total evacuation

EN54 compliant
programming available

Intelligent Power Management

Each zone has independent power management. Zones enter standby (near-zero power consumption) when no audio is present for a configurable period (5-60 minutes). Zones power up instantly (within 0.5 seconds) when audio is detected. This can reduce overall power consumption by up to 70% in multi-zone installations.

System Compatibility – T-77350Z

Required Controllers & Software
  • T-7700 / T-7700A / t-7700h – Server hardware
  • T-7700RP / T-7700RU – Broadcasting management software
  • Standard Ethernet switch, Cat5e or better
  • No external amplifiers required
Compatible Speaker Types
  • 100V constant voltage speakers (all T-7707, T-7782, T-7784 series)
  • 70V speakers (derate power by 50%)
  • Third-party 100V speakers with appropriate power taps
Optional Accessories
  • T-7771: External volume control (per zone)
  • T-7723: Fire alarm interface (16/32-ch)
  • T-7720: Wireless remote control
  • IR remote (included, replacement available)
Zone Control Options
  • T-7700RP software: Centralized zone scheduling and paging
  • T-7702A/M: Touch screen paging mics with zone selection
  • T-7771: Wall-mounted volume control (individual zone)
  • IR remote: Included, zone selection and volume
  • Front panel: 8 zone buttons for local override
Fire Alarm Integration
  • Direct connection to conventional fire panels (contact closure)
  • T-7723 for 16/32-zone addressable fire systems
  • Programmable evacuation zones (e.g., adjacent zones)
  • EN54 compliant configuration available
8-Zone Amplifier Family Comparison
Model Total Power Zones Output Type Form Factor Best For
T-77240Z 240W 8 100V 2U Schools, retail, offices
T-77350Z 350W 8 100V 2U Hospitals, large schools, conference centers
T-77500Z 500W 8 100V 3U Stadiums, factories, airports
Power Allocation Warning

The T-77350Z has a total power budget of 350W shared across 8 zones. Ensure total speaker wattage connected to all zones does not exceed 350W. Use the T-7700RP software to set per-zone power limits and prevent overload. Example: 8 zones × 43W speakers = 344W total (within budget).

Zone Grouping

Zones can be logically grouped in the T-7700RP software. For example, create an "All Call" group that activates zones 1-8 simultaneously, or "East Wing" group with zones 1,2,3. Group paging can be triggered from any T-7702A/M paging microphone with a single button press.

Typical Wiring Diagram

Server → Switch → T-77350Z → Zone 1-8 (100V) → 100V Speakers per zone

No external amplifiers needed. Each zone connects directly to its own speaker line. Fire alarm panel connected to fire input triggers programmed evacuation zones. T-7771 wall panels provide remote volume control per zone.