EXPLOSION-PROOF INTERCOM

T-7731

Explosion-Proof Wall-Mount IP Intercom for Hazardous Areas

IP66 • Ex db IIB T6 Gb • 30W External Speaker Output • Handset • Number Keys • One-Key Alarm

Ex db IIB T6 Gb • IP66 • 30W • HAZARDOUS AREAS
T-7731 Explosion-Proof Wall-Mount IP Intercom
T-7731 Front View
T-7731 Handset
T-7731 Certification
HAZARDOUS AREA

Explosion-Proof Intercom

T-7731 Ex db IIB T6 Gb IP66

Ex db IIB T6 Gb
IP66 Weatherproof
30W External Output
Handset
Number Keys
One-Key Alarm
Full-Duplex
PoE

Certified for hazardous environments. The T-7731 is an explosion-proof IP intercom certified Ex db IIB T6 Gb for use in Zone 1 and Zone 2 hazardous areas. With IP66 weatherproofing, a robust handset, and 30W external speaker output, it provides reliable communication in oil & gas, chemical plants, mining, and other explosive atmospheres.

Technical Specifications – T-7731

Model NumberT-7731
Product TypeExplosion-Proof Wall-Mount IP Intercom
Explosion ProtectionEx db IIB T6 Gb (Zone 1, Zone 2)
Ingress ProtectionIP66 (dust-tight, powerful water jets)
Enclosure MaterialHeavy-duty cast aluminum, epoxy-coated
External Speaker Output30W (drives external horn speaker)
HandsetExplosion-proof handset with PTT
Keypad12-key numeric keypad, one-key alarm
Network10/100Mbps Ethernet (RJ45)
Audio ProtocolsTCP/IP, UDP, HTTP, RTP, RTSP, SIP
Audio CodecsMP3, WAV, PCM, G.711, G.722
Audio CommunicationFull-Duplex with Echo Cancellation
Power SupplyPoE (802.3af) or DC 24V
Power Consumption≤ 15W
MountingWall mount with explosion-proof glands
Operating Temperature-20°C – 50°C
Humidity10% – 95% non-condensing
ColorGray / Industrial
CertificationsEx db IIB T6 Gb, CE, FCC, RoHS, IP66
Ex db IIB T6 Gb – What It Means

Ex = Explosion-protected • db = Flameproof enclosure • IIB = Gas group (ethylene, coke oven gas) • T6 = 85°C max surface temperature • Gb = Equipment protection level for Zone 1 (high risk). Certified for hazardous areas with explosive gases.

Product Overview – T-7731

The T-7731 is a specialized explosion-proof IP intercom designed for the most demanding hazardous environments. With Ex db IIB T6 Gb certification, it is approved for use in Zone 1 and Zone 2 areas where explosive gases may be present – oil rigs, chemical plants, refineries, mines, and grain handling facilities.

Certified Safety: The T-7731's flameproof enclosure is designed to contain any internal explosion and prevent ignition of the surrounding atmosphere. The robust cast aluminum housing with epoxy coating provides maximum protection in corrosive industrial environments.

Complete Communication: The unit includes an explosion-proof handset with push-to-talk operation, a 12-key numeric keypad for dialing, and a dedicated one-key alarm button for instant emergency calls. An external 30W speaker output drives a horn speaker for powerful paging.

IP66 Weatherproof: In addition to explosion protection, the T-7731 is IP66 rated – dust-tight and protected against powerful water jets, making it suitable for outdoor installations in all weather conditions.

Network Integration: Full SIP support enables direct integration with VoIP phone systems, intercom networks, and public address platforms. Power via PoE simplifies installation in hazardous areas.

Ex db IIB T6 Gb

Certified for Zone 1/2 hazardous areas. Flameproof enclosure prevents ignition.

IP66 Weatherproof

Dust-tight and protected against powerful water jets. Ideal for outdoor industrial use.

Handset + Keypad

Explosion-proof handset with PTT, 12-key dial pad, and one-key alarm button.

30W External Output

Drive external horn speakers for powerful paging in noisy environments.

Typical Applications
  • Oil & Gas Platforms: Safe communication in explosive atmospheres
  • Chemical Plants: Intercom for hazardous processing areas
  • Refineries: Emergency communication and paging
  • Mining Operations: Underground and surface hazardous zones
  • Grain Handling Facilities: Explosive dust environments

Explosion-Proof Features – T-7731

Ex db IIB T6 Gb Zone 1/2
IP66 Weatherproof
Handset Explosion-proof
12-Key Pad Numeric
One-Key Alarm Emergency
30W Output External
SIP VoIP
PoE 802.3af
Explosion-Proof Certification Details
Certification Details
Ex Marking Ex db IIB T6 Gb
Protection Type Flameproof enclosure (db)
Gas Group IIB (ethylene, coke oven gas, etc.)
Temperature Class T6 (85°C max surface temp)
EPL Level Gb (Zone 1 – high risk)
Applicable Zones Zone 1, Zone 2

Ex Certified

Zone 1 hazardous areas

Handset & Controls
Control Description
Handset Explosion-proof, PTT (push-to-talk) button
Keypad 12-key numeric (0-9, *, #)
Alarm Button Red one-key emergency call
LED Indicators Power, call status, alarm

Heavy-duty handset

PTT operation

External Speaker Output
Parameter Specification
Output Power 30W RMS
Speaker Type External horn speaker (not included)
Connection Explosion-proof gland, 2-core cable
Use Case Paging, announcements, alarms

30W output

Drive external horn

Environmental Ratings
Parameter Rating
Ingress ProtectionIP66
Operating Temperature-20°C to 50°C
Storage Temperature-30°C to 70°C
Humidity10% – 95% non-condensing
Corrosion ResistanceEpoxy-coated cast aluminum

IP66 – dust-tight, water jets

Wide temperature range

Installation in Hazardous Areas

The T-7731 must be installed by certified personnel following local regulations for hazardous area installations. All cable entries must use approved explosion-proof glands. The unit is designed for Zone 1 and Zone 2 areas with IIB gases. Not suitable for Zone 0 or IIC gases (hydrogen, acetylene).

System Compatibility – T-7731

Required Controllers & Software
  • T-7700 / T-7700A / t-7700h – Server hardware
  • T-7700RP / T-7700RU – Broadcasting management software
  • PoE switch (802.3af) or DC 24V power supply
  • SIP-compatible PBX for VoIP integration
SIP Compatibility
  • PBX Systems: Asterisk, 3CX, Cisco CUCM, BroadSoft
  • Endpoints: Any SIP-enabled desk phone, softphone
  • Codecs: G.711, G.722 for high-quality audio
Optional Accessories
  • Explosion-proof horn speaker: 30W, Ex certified
  • Ex-approved cable glands: For network and speaker connections
  • Mounting bracket: Heavy-duty industrial
Emergency Intercom Family
Model Type Protection Key Feature
T-7710 One-key outdoor IP55 500W amp, solar ready
T-7731 Explosion-proof Ex db IIB T6 Gb, IP66 Handset, 30W ext
T-7732 Industrial outdoor IP54 Steel casing, anti-tamper
T-7730/P IP66 decoding terminal IP66 16/30W amp
Power Options
  • PoE (802.3af): Standard power – one cable
  • 24V DC: External power for backup or non-PoE
  • Power consumption: ≤15W
Explosion-Proof vs Industrial Outdoor

The T-7731 is specifically certified for hazardous areas with explosive gases. Compare to other models:

  • T-7731 (Explosion-proof): Ex db IIB T6 Gb, IP66, handset, 30W external – for Zone 1/2 hazardous areas
  • T-7732 (Industrial outdoor): IP54, steel casing, anti-tamper – for general industrial outdoor use, not hazardous areas
  • T-7710 (One-key outdoor): IP55, 500W amp – for public safety, not hazardous

Choose T-7731 only when explosive atmosphere certification is required.

Important – Hazardous Area Installation

The T-7731 must be installed in accordance with local regulations for explosive atmospheres. Use only certified explosion-proof cable glands and conduit. Installation must be performed by qualified personnel. The unit is certified for IIB gases only – not for IIC (hydrogen, acetylene).

SIP Integration

The T-7731 supports standard SIP protocol for seamless integration with VoIP phone systems. Register to any SIP PBX for direct dialing, intercom groups, and emergency call routing. One-key alarm can be programmed to call a specific extension or group.

Typical Installation – Oil Refinery

T-7731 (wall-mounted) with explosion-proof horn speaker

Located in Zone 1 processing area. Connected via PoE from safe area. External 30W horn speaker provides paging. Handset allows two-way communication with control room. One-key alarm triggers emergency response.