32-CHANNEL FIRE ALARM INTERFACE

T-7723B

32-Channel IP Network Fire Alarm Interface with USB MP3 Player

32 Short-Circuit Inputs • 2U Rack Mount • USB MP3 Player • One-Key Alarm Cancel • WEB Management

32 INPUTS • 2U • USB MP3 • WEB MGMT • ALARM CANCEL
T-7723B 32-Channel IP Network Fire Alarm Interface
T-7723B Front Panel
T-7723B Rear Panel
T-7723B Connections
FIRE ALARM INTERFACE

32-Channel IP Fire Alarm Interface

T-7723B 32-CH WEB MGMT

32 Short-Circuit Inputs
2U Rack Mount
USB MP3 Player
One-Key Alarm Cancel
WEB Management
IP Network
Priority Override
Programmable

Complete fire alarm integration for IP audio systems. The T-7723B is a 32-channel IP network fire alarm interface that connects conventional fire alarm panels to your T-7700 series audio system. With 32 short-circuit inputs, USB MP3 player for emergency messages, and web-based management, it provides reliable, programmable emergency notification.

Technical Specifications – T-7723B

Model NumberT-7723B
Product Type32-Channel IP Network Fire Alarm Interface
Form Factor2U, 19" Rack Mount
Input Channels32 short-circuit inputs (dry contact)
Input TypeOpto-isolated, NO/COM
Input Voltage5-24V DC or dry contact
Network10/100Mbps Ethernet (RJ45)
Audio ProtocolsTCP/IP, UDP, HTTP, RTP, RTSP
Media PlaybackUSB 2.0 (MP3/WAV)
Alarm CancelOne-key front panel button
ManagementWeb-based configuration
PriorityProgrammable per input
Power SupplyAC 100-240V, 50/60Hz, internal
Power Consumption≤ 20W
Dimensions (WxDxH)483 x 200 x 88 mm (2U)
Weight3.5 kg
Operating Temperature0°C – 40°C
Humidity10% – 90% non-condensing
CertificationsCE, FCC, RoHS
32 Independent Alarm Inputs

Each of the 32 inputs can be individually programmed to trigger specific actions: play a message, activate zones, send notifications, or start a sequence. Inputs are opto-isolated for reliable operation in industrial environments.

Product Overview – T-7723B

The T-7723B is a professional 32-channel IP network fire alarm interface designed to connect conventional fire alarm panels to ITC T-7700 series IP audio systems. When a fire alarm triggers, the interface sends commands over the network to broadcast emergency messages, activate strobes, and notify security personnel.

32 Independent Inputs: Connect up to 32 zones from your fire alarm panel. Each input can be programmed with its own message, priority, and destination zones. Perfect for phased evacuation, floor-by-floor alerts, and area-specific warnings.

USB MP3 Player: The front-panel USB port allows you to store emergency messages directly on a USB drive. Pre-record "Evacuate", "Shelter in Place", and other alerts. Messages can be assigned to specific inputs.

One-Key Alarm Cancel: In an emergency, authorized personnel can silence alarms with a single button press on the front panel. Configurable to require password or key switch for security.

Web-Based Management: Configure all 32 inputs, assign messages, set priorities, and test the system through an intuitive web interface. No special software required – just a browser on your network.

Priority Override: Fire alarm inputs have the highest priority in the system, automatically overriding all other audio (background music, paging, etc.) to ensure emergency messages are heard.

2U Rack Mount: Standard 19" rack mount form factor fits neatly in equipment racks alongside other ITC components.

32 Inputs

Connect up to 32 fire alarm zones. Programmable per input for zone-specific alerts.

USB MP3 Player

Store emergency messages on USB drive. Play different messages for different zones.

One-Key Alarm Cancel

Silence alarms quickly with front panel button. Configurable security options.

Web Management

Configure and monitor from any browser. No proprietary software needed.

Typical Applications
  • Commercial Buildings: Connect fire alarm zones to IP paging system for voice evacuation
  • Hotels: Floor-by-floor emergency announcements
  • Schools: Integrate fire alarms with classroom speakers
  • Hospitals: Zone-specific alerts with priority override
  • Industrial Sites: Connect multiple alarm zones to IP network

Fire Alarm Features – T-7723B

32 Inputs Dry contact
USB MP3 Messages
Alarm Cancel One-key
WEB Mgmt Configuration
2U Rack 19" mount
Priority Override
Voice Evac Programmable
Opto-Isolated Reliable
Input Specifications
Parameter Specification
Number of Inputs 32 (individually programmable)
Input Type Opto-isolated, dry contact (NO/COM)
Input Voltage Range 5-24V DC or contact closure
Isolation Voltage 2500V RMS
Response Time < 50ms
Debounce Time 20ms – 500ms (configurable)

32 zones

Independent control

Programmable Actions per Input
Action Description
Play Message Select MP3 file from USB (e.g., "Evacuate Floor 3")
Activate Zones Choose which speaker zones receive the message
Priority Level Set priority (1-10, 1 highest) to override other audio
Repeat Count Number of times to repeat message (1-10, continuous)
Notification Send email/SMS to security personnel
Trigger Output Activate relay output for external strobe/siren

Fully programmable

Per input

USB MP3 Player
Parameter Specification
USB Version USB 2.0, FAT32
Supported Formats MP3, WAV
File Organization Files named by input number (e.g., 01.MP3 for input 1)
Maximum Files 32 (one per input)
Bit Rate 32-320 kbps

USB storage

Easy message updates

Front Panel Controls
  • Alarm Cancel button: Red button with protective cover – silences all active alarms
  • USB port: Front-panel for MP3 files
  • Status LEDs: Power, network, input active (1-32 via bank select)
  • LCD display: 2-line display for status and configuration

One-key cancel

Emergency silence

Web Management Interface

Access the T-7723B through any web browser on your network. Configure all 32 inputs, upload messages, set priorities, view alarm logs, and test the system. Password protected with multiple user levels (admin, operator, viewer).

System Compatibility – T-7723B

Required Controllers & Software
  • T-7700 / T-7700A / t-7700h – Server hardware
  • T-7700RP / T-7700RU – Broadcasting management software
  • Standard Ethernet switch
  • Fire alarm panel with dry contact outputs
Compatible Fire Panels
  • Any conventional fire alarm panel with relay/dry contact outputs
  • Addressable panels via zone interface modules
  • 5-24V DC or potential-free contacts
Optional Accessories
  • USB drive: For storing MP3 messages
  • Rack mount screws: Included
  • Connector kit: Terminal blocks for inputs
T-7723 vs T-7723B Comparison
Model Inputs Form Factor USB MP3 Web Mgmt
T-7723 16 1U No No
T-7723B 32 2U Yes Yes
System Integration
  • Priority: Fire alarm inputs can be set to highest priority, overriding all other audio
  • Zone mapping: Each input can trigger any combination of speaker zones
  • Logging: All alarms logged on T-7700 server for compliance
  • Email alerts: Send notifications on alarm activation
Power
  • AC power: 100-240V internal supply
  • Power consumption: ≤20W
Typical Fire Alarm Integration Diagram

Fire Alarm Panel (Zone 1-32) → T-7723B → Network Switch → T-7700 Server → Zone Amplifiers/Speakers

Example: Fire alarm zone 3 triggers → T-7723B plays "Evacuate Floor 3" from USB → message broadcast to all speakers on floor 3. Other floors receive different messages or remain in background music mode.

Life Safety Note

The T-7723B is designed for use in fire alarm systems but must be installed in accordance with local codes and standards. Regular testing is required. Always consult with a licensed fire alarm contractor for system design and approval.

Web Configuration Example

Input 1: Zone 1 message "Fire on Floor 1" – priority 1 – zones 1,2,3 – repeat 3 times – email security. Input 2: "Fire on Floor 2" – zones 4,5,6 – etc. All configurable via web interface with no programming required.

Typical Installation – Office Building

T-7723B in server room, connected to fire panel and network

Fire alarm zones 1-8 connected to T-7723B inputs. USB drive contains pre-recorded evacuation messages for each floor. When alarm triggers, appropriate message plays through ceiling speakers. Security receives email alert. Front panel alarm cancel allows authorized silencing.