Compact 16-channel fire alarm integration. The T-7723 is a 1U rack-mount IP network fire alarm interface that connects conventional fire alarm panels to your T-7700 series audio system. With 16 short-circuit inputs, USB MP3 player for emergency messages, and one-key alarm cancel, it provides reliable emergency notification for smaller installations.
| Model Number | T-7723 |
| Product Type | 16-Channel IP Network Fire Alarm Interface |
| Form Factor | 1U, 19" Rack Mount |
| Input Channels | 16 short-circuit inputs (dry contact) |
| Input Type | Opto-isolated, NO/COM |
| Input Voltage Range | 5-24V DC or dry contact |
| Isolation Voltage | 2500V RMS |
| Network | 10/100Mbps Ethernet (RJ45) |
| Audio Protocols | TCP/IP, UDP, HTTP, RTP, RTSP |
| Media Playback | USB 2.0 (MP3/WAV) |
| Alarm Cancel | One-key front panel button |
| Priority | Programmable per input |
| Response Time | < 50ms |
| Power Supply | AC 100-240V, 50/60Hz, internal |
| Power Consumption | ≤ 15W |
| Dimensions (WxDxH) | 483 x 200 x 44 mm (1U) |
| Weight | 2.8 kg |
| Operating Temperature | 0°C – 40°C |
| Humidity | 10% – 90% non-condensing |
| Certifications | CE, FCC, RoHS |
Each of the 16 inputs can be individually programmed to trigger specific actions: play a message, activate zones, send notifications, or start a sequence. Inputs are opto-isolated for reliable operation in industrial environments.
The T-7723 is a compact 16-channel IP network fire alarm interface designed for smaller installations requiring fire alarm integration with ITC T-7700 series IP audio systems. In a space-saving 1U chassis, it provides all the essential features for voice evacuation and emergency notification.
16 Independent Inputs: Connect up to 16 zones from your fire alarm panel. Each input can be programmed with its own message, priority, and destination zones. Perfect for floor-by-floor alerts in smaller buildings.
USB MP3 Player: The front-panel USB port allows you to store emergency messages directly on a USB drive. Pre-record "Evacuate", "Shelter in Place", and other alerts. Messages can be assigned to specific inputs.
One-Key Alarm Cancel: In an emergency, authorized personnel can silence alarms with a single button press on the front panel. Configurable to require password or key switch for security.
Priority Override: Fire alarm inputs have the highest priority in the system, automatically overriding all other audio (background music, paging, etc.) to ensure emergency messages are heard.
1U Compact Design: Fits in any standard 19" rack, ideal for smaller equipment rooms and budget-conscious installations.
Connect up to 16 fire alarm zones. Programmable per input for zone-specific alerts.
Store emergency messages on USB drive. Play different messages for different zones.
Silence alarms quickly with front panel button. Configurable security options.
Space-saving design fits in any 19" rack. Ideal for smaller installations.
| Parameter | Specification |
|---|---|
| Number of Inputs | 16 (individually programmable) |
| Input Type | Opto-isolated, dry contact (NO/COM) |
| Input Voltage Range | 5-24V DC or contact closure |
| Isolation Voltage | 2500V RMS |
| Response Time | < 50ms |
| Debounce Time | 20ms – 500ms (configurable) |
16 zones
Independent control
| Action | Description |
|---|---|
| Play Message | Select MP3 file from USB (e.g., "Evacuate Floor 3") |
| Activate Zones | Choose which speaker zones receive the message |
| Priority Level | Set priority (1-10, 1 highest) to override other audio |
| Repeat Count | Number of times to repeat message (1-10, continuous) |
| Notification | Send email/SMS to security personnel |
Fully programmable
Per input
| Parameter | Specification |
|---|---|
| USB Version | USB 2.0, FAT32 |
| Supported Formats | MP3, WAV |
| File Organization | Files named by input number (e.g., 01.MP3 for input 1) |
| Maximum Files | 16 (one per input) |
| Bit Rate | 32-320 kbps |
USB storage
Easy message updates
One-key cancel
Emergency silence
Configure all 16 inputs via T-7700RP software. Set message assignments, zone destinations, priority levels, and repeat counts. No local programming required – all settings centrally managed.
| Model | Inputs | Form Factor | USB MP3 | Web Mgmt |
|---|---|---|---|---|
| T-7723 | 16 | 1U | Yes | No |
| T-7723B | 32 | 2U | Yes | Yes |
Fire Alarm Panel (Zone 1-16) → T-7723 → Network Switch → T-7700 Server → Zone Amplifiers/Speakers
Example: Fire alarm zone 3 triggers → T-7723 plays "Evacuate Floor 3" from USB → message broadcast to all speakers on floor 3.
The T-7723 is designed for use in fire alarm systems but must be installed in accordance with local codes and standards. Regular testing is required. Always consult with a licensed fire alarm contractor for system design and approval.
T-7723 in equipment rack, connected to fire panel and network
Fire alarm zones 1-8 connected to T-7723 inputs. USB drive contains pre-recorded evacuation messages for each floor. When alarm triggers, appropriate message plays through ceiling speakers. Front panel alarm cancel allows authorized silencing.