Modular Cabinet System

FW434 - Fire Alarm System Equipment Enclosure

Modular Design • System Integration • Professional Installation • Equipment Protection

EQUIPMENT ENCLOSURE
UL 508A Listed
UL 508A NEMA 12 IP54 Rated CE Certified
Standard Size: 24"W × 36"H × 8"D

Modular Cabinet System

FW434

Modular
Expandable Design
Add sections as needed
UL 508A Listed
Modular Design
Quality Tested
Easy Installation

The FW434 Modular Cabinet System is a professional-grade enclosure designed specifically for fire alarm system components and accessories. Featuring a modular design that allows for easy expansion and customization, this cabinet provides organized, secure housing for control panels, power supplies, batteries, and peripheral devices. With UL 508A listing and NEMA 12 rating, it offers reliable protection for critical life safety equipment in commercial and industrial applications.

Modular Design

Add expansion sections as your system grows. Standardized mounting for easy integration.

Standardized Mounting

Pre-drilled mounting holes and DIN rail mounting for all major fire alarm components.

Secure Enclosure

Lockable doors with tamper-resistant hardware protect sensitive equipment.

Standard Sizes

Available in 24", 36", and 48" widths

Easy Assembly

Tool-less assembly with clear instructions

Cable Management

Integrated cable routing and management

Request Quote

Get pricing and availability for your project requirements

Contact Sales

Technical Specifications

Model NumberFW434
Product NameModular Cabinet System
Device TypeEquipment Enclosure
Standard Size24"W × 36"H × 8"D (610mm × 914mm × 203mm)
Material16-gauge galvanized steel
FinishPowder coat finish, light gray (RAL 7035)
Door ConfigurationSingle door, hinged right (reversible)
Door Material16-gauge steel with window option
WindowPolycarbonate, 1/8" thick (optional)
LockingCam lock with 2 keys (high security optional)
Mounting RailsDIN rail (35mm × 7.5mm), 4 included
Mounting HolesPre-punched 1/4" holes on 1" centers
Weight Capacity200 lbs (91 kg) distributed load
CertificationsUL 508A, NEMA 12, IP54, CE
ManufacturerMaple Armor / Tongfang BMS
Ingress ProtectionIP54 (Dust and splash resistant)
NEMA RatingNEMA 12 (Dust, dirt, and dripping liquids)
GroundingIntegrated grounding bus bar
Cable EntryKnockouts: (6) 1/2", (4) 3/4", (2) 1"
VentilationVented top and bottom (screened)
ColorLight gray standard (custom colors available)
MountingWall mount or floor standing (legs optional)
InstallationTool-less assembly (basic tools required)
Warranty10-Year Limited Warranty
Accessories IncludedMounting hardware, DIN rails, leveling feet
Available Sizes & Configurations
Standard 24"

24"W × 36"H × 8"D - Ideal for small to medium systems

Large 36"

36"W × 48"H × 12"D - For larger control systems

Expansion 48"

48"W × 72"H × 12"D - Maximum capacity systems

Product Overview

The FW434 Modular Cabinet System is engineered specifically for professional fire alarm system installations, providing organized, secure, and accessible housing for critical life safety equipment. Its modular design allows for easy expansion as system requirements grow, while standardized mounting features ensure compatibility with all major fire alarm components. The cabinet's robust construction meets UL 508A industrial control panel standards and NEMA 12 environmental ratings, making it suitable for both commercial and industrial applications where equipment protection and professional appearance are essential.

UL 508A Listed

Certified to UL Standard 508A for Industrial Control Panels, ensuring safe and reliable enclosure for electrical equipment in accordance with North American safety standards.

Modular Expandable Design

Start with a basic configuration and add expansion sections as your system grows. Standardized connections make expansion simple and cost-effective.

Professional Protection

NEMA 12 and IP54 ratings provide protection against dust, dirt, and dripping liquids, ensuring reliable operation in challenging environments.

Compatible Equipment
Maple Armor
Control Panels
All series FACPs and power supplies
Battery Packs
Backup Power
24VDC sealed lead-acid batteries
Peripherals
System Accessories
Annunciators, relays, interfaces
Certifications & Compliance

UL 508A: Industrial Control Panels

NEMA 12: Industrial Enclosures

IP54: Ingress Protection Rating

CE Mark: European Conformity

RoHS: Restriction of Hazardous Substances

Local Codes: Meets electrical enclosure requirements

Product Features

Construction Features
  • 16-gauge galvanized steel construction
  • Powder coat finish for corrosion resistance
  • Reinforced door frame and hinges
  • Removable side panels for easy access
  • Sealed seams for environmental protection
Functional Features
  • Modular design for easy expansion
  • Standardized DIN rail mounting
  • Integrated cable management system
  • Grounding bus bar with terminals
  • Ventilation with dust filters
Installation Features
  • Pre-punched mounting holes
  • Standardized knockout pattern
  • Tool-less assembly design
  • Leveling feet for floor mounting
  • Clear assembly instructions
Security & Access Features
  • Cam lock with two keys standard
  • Tamper-resistant hardware
  • Window option for visual inspection
  • 180° door opening for full access
  • Reversible door hinge
Professional Enclosure Importance: Proper equipment cabinets are essential for fire alarm system reliability and longevity. The FW434 provides organized, protected housing that prevents dust accumulation, reduces electromagnetic interference, and maintains proper ventilation for heat dissipation. Its modular design allows systems to expand without requiring complete replacement, while standardized mounting ensures consistent installation quality and ease of maintenance.

Installation & Configuration

Installation Guidelines
  • Install in accessible, well-ventilated location
  • Maintain minimum 36" clearance in front
  • Secure to wall or floor per local codes
  • Ensure proper grounding connection
  • Route cables through provided knockouts
Mounting Requirements
Space Requirements

Minimum 36" clearance in front for access and maintenance.

Mounting Hardware

Hardware included for wall or floor mounting. Concrete anchors sold separately.

Electrical Requirements

Ensure proper grounding via included bus bar. Follow NEC requirements.

Installation Steps
  1. Select installation location with proper clearance
  2. Assemble cabinet frame following provided instructions
  3. Mount DIN rails at desired heights
  4. Install cabinet on wall or floor using provided hardware
  5. Install grounding bus bar and connect to building ground
  6. Mount equipment components on DIN rails
  7. Route cables through knockouts and manage with included ties
  8. Connect equipment following manufacturer instructions
  9. Install door and adjust as needed
  10. Label all components and circuits
Configuration Options
Expansion Modules

Add side or top expansion sections for additional equipment capacity.

Accessory Options

Add shelves, drawers, or internal lighting as needed.

Applications & Compatibility

Compatible Systems
  • Maple Armor fire alarm control panels
  • Emergency voice evacuation systems
  • Fire pump controllers and accessories
  • Security and access control systems
Ideal Applications
  • Commercial building fire alarm systems
  • Industrial facility control rooms
  • Hospital and healthcare facilities
  • Educational institutions
  • Data centers and telecom rooms
Application Scenarios
Office Buildings

Central fire alarm control panel enclosure in electrical rooms.

Industrial Facilities

Protected housing for control equipment in manufacturing areas.

Educational Facilities

Secure cabinet for life safety systems in schools and universities.

Benefits

Code Compliance: Meets UL 508A and NEC requirements

Equipment Protection: NEMA 12 and IP54 rated

Professional Installation: Organized, accessible equipment layout

Cost Effective: Modular design reduces future costs

Easy Maintenance: Organized layout simplifies service

Future-Proof: Expandable as system requirements grow

Maintenance Requirements
Visual Inspection

Monthly
Check for damage and cleanliness

Cleaning

Quarterly
Clean exterior and check ventilation

Security Check

Annual
Verify lock operation and security