Zone Module

FW2841 - Hybrid Zone Interface Module

Dual-Zone Monitoring • Intelligent Detection • System Integration

HYBRID ZONE MODULE
UL Listed

Zone Module

FW2841

UL Listed
Dual Zone
Quality Tested
Easy Install

The FW2841 Zone Module is a hybrid interface module designed for fire alarm zone monitoring and control. It provides dual-zone capability with intelligent monitoring features, making it ideal for complex building environments requiring precise zone-based fire detection and control.

Technical Specifications

Model NumberFW2841
Product NameZone Module
CategoryHybrid Zone Module
CertificationUL Listed (UL864)
ManufacturerMaple Armor / Tongfang
Warranty2-Year Standard
Zone Capacity2 Independent Zones (Style B/Class B)
Monitoring PointsUp to 50 devices per zone (max 100 total)
Input TypesSmoke detectors, Heat detectors, Manual call points
Output Types1 Form C relay output (common for both zones)
Relay Rating2A @ 30VDC, 0.5A @ 120VAC
Operating Voltage15-32VDC
Current ConsumptionStandby: 5mA, Active: 25mA
Communication ProtocolProprietary MAP Protocol
Address Range1-159 (Programmable)
Zone IsolationYes, independent zone monitoring
Zone SupervisionStyle B (Class B) with EOL supervision
Zone LED IndicatorsIndividual LEDs for Zone 1 and Zone 2 status
Operating Temperature-10°C to +55°C (14°F to 131°F)
Storage Temperature-20°C to +70°C (-4°F to 158°F)
Humidity10% to 93% RH (Non-condensing)
EnclosurePlastic, DIN Rail Mountable
Dimensions (HxWxD)4.5" x 3.2" x 1.4" (114 x 81 x 36mm)
Weight0.45 lbs (0.20 kg)
Wire Gauge12-22 AWG for field wiring
LED IndicatorsPower, Communication, Zone 1, Zone 2, Relay
Short Circuit ProtectionYes, auto-resetting
Ground Fault DetectionYes, per zone

Product Overview

The FW2841 Zone Module is a hybrid interface device that provides dual-zone monitoring capabilities for fire alarm systems. It combines zone monitoring with relay control functions, allowing for comprehensive fire detection and system integration in complex building environments.

Dual Zone Monitoring

Two independent Style B (Class B) zones with individual status monitoring and isolation.

UL Listed Safety

Certified to UL864 standards for fire alarm system components, ensuring code compliance.

Intelligent Detection

Advanced microprocessor-based design with programmable zone logic and detailed reporting.

Zone Monitoring Applications

Building floor separation zones

Tenant space isolation

Special hazard area monitoring

Elevator lobby zones

Mechanical room monitoring

Stairwell pressurization zones

Atrium smoke detection zones

High-rise floor zoning

Product Features

Zone Monitoring Features
  • 2 independent Style B (Class B) zones
  • Up to 50 devices per zone (100 total)
  • Individual zone isolation and monitoring
  • End-of-line (EOL) resistor supervision
  • Ground fault detection per zone
  • Short circuit protection with auto-reset
Control Features
  • 1 Form C relay output (common relay)
  • 2A @ 30VDC contact rating
  • 0.5A @ 120VAC contact rating
  • Programmable activation logic (zone 1 OR zone 2)
  • Manual override capability
  • LED status indication for relay
Communication Features
  • Proprietary MAP communication protocol
  • Programmable address (1-159)
  • Real-time zone status reporting
  • Two-way communication with FACP
  • Automatic device recognition
  • Individual zone fault reporting
Diagnostic Features
  • Individual LED indicators for each zone
  • Power and communication status LEDs
  • Zone fault detection and reporting
  • Relay contact monitoring
  • Self-test diagnostics
  • Communication fault detection
Flexible Zone Configuration: The FW2841 Zone Module supports various zone configurations including: Zone 1 only activation, Zone 2 only activation, Zone 1 OR Zone 2 activation (common relay), or individual zone reporting with separate control logic. This flexibility makes it ideal for complex building layouts.

Installation & Configuration

DIN Rail Mount
Standard 35mm DIN rail mounting
Panel Mount
Direct panel mounting option
Enclosure Mount
Mount within system enclosures
Installation Guidelines
  • Mount in dry, protected location
  • Ensure proper ventilation around module
  • Follow NEC, NFPA 72, and local electrical codes
  • Use proper cable strain relief
  • Maintain minimum 2" clearance around unit
  • Separate zone wiring for isolation
Wiring Requirements
Power Wiring

18-22 AWG for 15-32VDC power from FACP or separate supply.

Data Wiring

Twisted pair for MAP communication (18-22 AWG).

Zone Wiring

14-22 AWG for zone circuits with proper EOL resistors.

Relay Wiring

14-22 AWG for relay load circuits based on current requirements.

Configuration Steps
  1. Mount the Zone Module on DIN rail or panel
  2. Connect power supply (15-32VDC)
  3. Connect data communication cables to FACP
  4. Connect Zone 1 wiring with EOL resistor at end of line
  5. Connect Zone 2 wiring with EOL resistor at end of line
  6. Connect relay output to controlled device if used
  7. Power up and assign module address via FACP programming
  8. Configure zone monitoring parameters as required
  9. Configure relay activation logic (zone 1, zone 2, or both)
  10. Test zone monitoring and relay operation
  11. Verify operation through system diagnostics
Zone Wiring Guidelines
Zone 1 Wiring

Connect detectors and devices for Zone 1 monitoring.

Zone 2 Wiring

Connect detectors and devices for Zone 2 monitoring.

EOL Resistors

Install appropriate EOL resistors (typically 4.7kΩ).

Compatibility & Applications

Compatible Systems
  • Maple Armor FW2000 Series
  • Maple Armor FW2100 Series
  • Maple Armor FW2200 Series
  • All Maple Armor FACP with MAP protocol
  • Compatible with legacy Tongfang systems
Typical Applications
  • Building floor zoning (multi-tenant)
  • Special hazard area isolation
  • High-rise building floor separation
  • Mixed occupancy building zoning
  • Healthcare facility zone isolation
  • Industrial process area zoning
Application Scenarios
Office Buildings

Separate tenant spaces with independent zone monitoring.

Healthcare Facilities

Isolate patient care areas from support spaces.

Industrial Facilities

Separate hazardous process areas from storage.

Benefits

Dual Zone: Independent monitoring of two zones

Code Compliance: UL Listed for regulatory requirements

Flexible: Multiple zone and relay configurations

Reliable: Industrial-grade components

Scalable: Expand system monitoring capabilities

Serviceable: Easy maintenance and troubleshooting