FW2841 - Hybrid Zone Interface Module
Dual-Zone Monitoring • Intelligent Detection • System Integration
FW2841
The FW2841 Zone Module is a hybrid interface module designed for fire alarm zone monitoring and control. It provides dual-zone capability with intelligent monitoring features, making it ideal for complex building environments requiring precise zone-based fire detection and control.
| Model Number | FW2841 |
| Product Name | Zone Module |
| Category | Hybrid Zone Module |
| Certification | UL Listed (UL864) |
| Manufacturer | Maple Armor / Tongfang |
| Warranty | 2-Year Standard |
| Zone Capacity | 2 Independent Zones (Style B/Class B) |
| Monitoring Points | Up to 50 devices per zone (max 100 total) |
| Input Types | Smoke detectors, Heat detectors, Manual call points |
| Output Types | 1 Form C relay output (common for both zones) |
| Relay Rating | 2A @ 30VDC, 0.5A @ 120VAC |
| Operating Voltage | 15-32VDC |
| Current Consumption | Standby: 5mA, Active: 25mA |
| Communication Protocol | Proprietary MAP Protocol |
| Address Range | 1-159 (Programmable) |
| Zone Isolation | Yes, independent zone monitoring |
| Zone Supervision | Style B (Class B) with EOL supervision |
| Zone LED Indicators | Individual LEDs for Zone 1 and Zone 2 status |
| Operating Temperature | -10°C to +55°C (14°F to 131°F) |
| Storage Temperature | -20°C to +70°C (-4°F to 158°F) |
| Humidity | 10% to 93% RH (Non-condensing) |
| Enclosure | Plastic, DIN Rail Mountable |
| Dimensions (HxWxD) | 4.5" x 3.2" x 1.4" (114 x 81 x 36mm) |
| Weight | 0.45 lbs (0.20 kg) |
| Wire Gauge | 12-22 AWG for field wiring |
| LED Indicators | Power, Communication, Zone 1, Zone 2, Relay |
| Short Circuit Protection | Yes, auto-resetting |
| Ground Fault Detection | Yes, per zone |
The FW2841 Zone Module is a hybrid interface device that provides dual-zone monitoring capabilities for fire alarm systems. It combines zone monitoring with relay control functions, allowing for comprehensive fire detection and system integration in complex building environments.
Two independent Style B (Class B) zones with individual status monitoring and isolation.
Certified to UL864 standards for fire alarm system components, ensuring code compliance.
Advanced microprocessor-based design with programmable zone logic and detailed reporting.
Building floor separation zones
Tenant space isolation
Special hazard area monitoring
Elevator lobby zones
Mechanical room monitoring
Stairwell pressurization zones
Atrium smoke detection zones
High-rise floor zoning
18-22 AWG for 15-32VDC power from FACP or separate supply.
Twisted pair for MAP communication (18-22 AWG).
14-22 AWG for zone circuits with proper EOL resistors.
14-22 AWG for relay load circuits based on current requirements.
Connect detectors and devices for Zone 1 monitoring.
Connect detectors and devices for Zone 2 monitoring.
Install appropriate EOL resistors (typically 4.7kΩ).
Separate tenant spaces with independent zone monitoring.
Isolate patient care areas from support spaces.
Separate hazardous process areas from storage.
Dual Zone: Independent monitoring of two zones
Code Compliance: UL Listed for regulatory requirements
Flexible: Multiple zone and relay configurations
Reliable: Industrial-grade components
Scalable: Expand system monitoring capabilities
Serviceable: Easy maintenance and troubleshooting