FW2811 - Fire Alarm Monitoring Module
UL Listed • Intelligent Monitoring • System Integration
FW2811
The FW2811 Input Module is a high-performance fire alarm monitoring component designed for modern life safety systems. Part of the Maple Armor 2025 series, providing reliability and code compliance for complex building environments.
| Model Number | FW2811 |
| Product Name | Input Module |
| Category | Monitoring Module |
| Certification | UL Listed (UL864) |
| Manufacturer | Maple Armor / Tongfang |
| Warranty | 2-Year Standard |
| Input Channels | 2 Style B (Class B) Inputs |
| Operating Voltage | 15-32VDC |
| Current Consumption | Standby: 2mA, Active: 10mA |
| Communication Protocol | Proprietary MAP Protocol |
| Address Range | 1-159 (Programmable) |
| Operating Temperature | -10°C to +55°C (14°F to 131°F) |
| Storage Temperature | -20°C to +70°C (-4°F to 158°F) |
| Humidity | 10% to 93% RH (Non-condensing) |
| Enclosure | Plastic, DIN Rail Mountable |
| Dimensions (HxWxD) | 4.0" x 2.5" x 1.2" (102 x 64 x 30mm) |
| Weight | 0.3 lbs (0.14 kg) |
| Wire Gauge | 12-22 AWG for field wiring |
| LED Indicators | Power, Communication, Fault |
The FW2811 Input Module is an intelligent monitoring device designed for fire alarm systems. It monitors conventional input circuits and reports their status to the fire alarm control panel, providing essential monitoring capabilities for various building systems.
Certified to UL864 standards for fire alarm system components, ensuring compliance with North American safety requirements.
Advanced microprocessor-based design with real-time status reporting and diagnostic capabilities.
Simple DIN rail mounting with clear terminal connections and LED status indicators.
Seamless integration with Maple Armor FACP
Monitors dry contact devices
Supports conventional input circuits
Real-time status reporting
Fault detection and reporting
Supervised wiring monitoring
Programmable address
Automatic configuration
18-22 AWG for 15-32VDC power from FACP or separate supply.
Twisted pair for MAP communication (18-22 AWG).
12-22 AWG for field wiring to monitored devices.
Monitor sprinkler system water flow and pressure switches.
Monitor specialized detection devices and manual stations.
Monitor fire pump status and specialized alarm devices.
Code Compliance: UL Listed for regulatory compliance
Time-Saving: Quick installation and configuration
Flexible: Multiple monitoring applications
Reliable: Industrial-grade construction
Scalable: Expand monitoring capabilities
Serviceable: Easy maintenance and troubleshooting