Input Module

FW2811 - Fire Alarm Monitoring Module

UL Listed • Intelligent Monitoring • System Integration

UL LISTED MONITORING MODULE
UL Listed

Input Module

FW2811

UL Listed
Intelligent
Quality Tested
Easy Install

The FW2811 Input Module is a high-performance fire alarm monitoring component designed for modern life safety systems. Part of the Maple Armor 2025 series, providing reliability and code compliance for complex building environments.

Technical Specifications

Model NumberFW2811
Product NameInput Module
CategoryMonitoring Module
CertificationUL Listed (UL864)
ManufacturerMaple Armor / Tongfang
Warranty2-Year Standard
Input Channels2 Style B (Class B) Inputs
Operating Voltage15-32VDC
Current ConsumptionStandby: 2mA, Active: 10mA
Communication ProtocolProprietary MAP Protocol
Address Range1-159 (Programmable)
Operating Temperature-10°C to +55°C (14°F to 131°F)
Storage Temperature-20°C to +70°C (-4°F to 158°F)
Humidity10% to 93% RH (Non-condensing)
EnclosurePlastic, DIN Rail Mountable
Dimensions (HxWxD)4.0" x 2.5" x 1.2" (102 x 64 x 30mm)
Weight0.3 lbs (0.14 kg)
Wire Gauge12-22 AWG for field wiring
LED IndicatorsPower, Communication, Fault

Product Overview

The FW2811 Input Module is an intelligent monitoring device designed for fire alarm systems. It monitors conventional input circuits and reports their status to the fire alarm control panel, providing essential monitoring capabilities for various building systems.

UL Listed Safety

Certified to UL864 standards for fire alarm system components, ensuring compliance with North American safety requirements.

Intelligent Monitoring

Advanced microprocessor-based design with real-time status reporting and diagnostic capabilities.

Easy Installation

Simple DIN rail mounting with clear terminal connections and LED status indicators.

System Integration

Seamless integration with Maple Armor FACP

Monitors dry contact devices

Supports conventional input circuits

Real-time status reporting

Fault detection and reporting

Supervised wiring monitoring

Programmable address

Automatic configuration

Product Features

Monitoring Capabilities
  • 2 Style B (Class B) input circuits
  • Monitors dry contact devices
  • Supports conventional alarm inputs
  • Supervised wiring monitoring
  • End-of-line resistor monitoring
Communication Features
  • Proprietary MAP communication protocol
  • Programmable address (1-159)
  • Real-time status reporting
  • Two-way communication
  • Automatic device recognition
Diagnostic Features
  • LED status indicators (Power, Comm, Fault)
  • Circuit fault detection
  • Open circuit detection
  • Short circuit detection
  • Ground fault detection
Physical Features
  • Flame-retardant plastic enclosure
  • DIN rail mounting (35mm standard)
  • Screw terminal connections
  • Clear labeling and indicators
  • Compact design for space efficiency
UL Listed: The FW2811 Input Module is certified to UL864 standards, ensuring compliance with North American fire alarm system requirements for commercial and industrial applications.

Installation & Configuration

DIN Rail Mount
Standard 35mm DIN rail mounting
Panel Mount
Direct panel mounting option
Enclosure Mount
Mount within system enclosures
Installation Guidelines
  • Mount in dry, protected location
  • Ensure proper ventilation
  • Follow NEC and local codes
  • Use proper cable strain relief
  • Maintain minimum clearance around unit
Wiring Requirements
Power Wiring

18-22 AWG for 15-32VDC power from FACP or separate supply.

Data Wiring

Twisted pair for MAP communication (18-22 AWG).

Input Circuits

12-22 AWG for field wiring to monitored devices.

Configuration Steps
  1. Mount the Input Module on DIN rail or panel
  2. Connect power supply (15-32VDC)
  3. Connect data communication cables to FACP
  4. Connect input circuits to monitored devices
  5. Install end-of-line resistors on input circuits
  6. Power up and assign module address via FACP programming
  7. Test all monitored circuits

Compatibility & Applications

Compatible Systems
  • Maple Armor FW2000 Series
  • Maple Armor FW2100 Series
  • Maple Armor FW2200 Series
  • All Maple Armor FACP with MAP protocol
Monitored Devices
  • Manual pull stations
  • Water flow switches
  • Pressure switches
  • Supervisory switches
  • Conventional smoke detectors
Application Scenarios
Commercial Buildings

Monitor sprinkler system water flow and pressure switches.

Industrial Facilities

Monitor specialized detection devices and manual stations.

Healthcare Facilities

Monitor fire pump status and specialized alarm devices.

Benefits

Code Compliance: UL Listed for regulatory compliance

Time-Saving: Quick installation and configuration

Flexible: Multiple monitoring applications

Reliable: Industrial-grade construction

Scalable: Expand monitoring capabilities

Serviceable: Easy maintenance and troubleshooting