Abort Station

FW2732 - Fire Suppression System Abort Control

Key-Operated • System Abort • Emergency Override • Life Safety

SYSTEM ABORT CONTROL
NFPA 2001 Compliant
UL Listed NFPA 2001 FM Approved CE Certified
Key-Operated Security Switch

Abort Station

FW2732

Key-Operated
Secure Abort Control
Authorized system abort only
IMPORTANT: Abort stations are for authorized personnel only. Use only when automatic system discharge is not required or during system maintenance.
UL Listed
System Abort
Quality Tested
Easy Installation

The FW2732 Abort Station is a critical safety device designed to provide authorized personnel with the ability to abort impending fire suppression system discharges. Featuring a key-operated switch mechanism, it prevents unauthorized access while allowing trained personnel to stop automatic system activation when false alarms occur or during system maintenance. This device is essential for protecting expensive suppression agents and preventing unnecessary discharge that could cause damage or downtime.

Clean Agent Systems

Abort control for FM-200, Novec 1230, and other clean agent systems

CO₂ Systems

Emergency abort for high-pressure and low-pressure carbon dioxide systems

Water Mist Systems

Abort control for water mist and deluge suppression systems

Request Quote

Get pricing and availability for your suppression system

Contact Sales

Technical Specifications

Model NumberFW2732
Product NameAbort Station
Device TypeSuppression System Abort Control
Operation MethodKey-Operated Switch
Switch TypeMaintained Contact (ON-OFF-ON)
Key SecurityRestricted keyway (2 keys provided)
CertificationsUL Listed, NFPA 2001, FM Approved, CE
ManufacturerMaple Armor / Tongfang BMS
System CompatibilityAll major suppression systems
Contact ConfigurationSPDT (Single Pole Double Throw)
Contact Rating24VDC/120VAC, 5A @ 30VDC, 3A @ 120VAC
Contact Resistance< 50 mΩ when closed
Operation IndicationRed LED (Abort Active), Green LED (Normal)
Reset MethodKey turn to normal position
Operating Temperature Range14°F to 120°F (-10°C to 49°C)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Relative Humidity10% to 95% RH (Non-condensing)
Impact ResistanceIK08 (High impact resistant)
Dimensions5.9" x 5.9" x 2.8" (150mm x 150mm x 70mm)
Weight16.9 oz (480 g)
ColorYellow (Standard) with "ABORT STATION" lettering
MountingWall Mount, 60" AFF recommended
TerminalsScrew terminals, 12-22 AWG wire
IP RatingIP54 (Dust and splash resistant)
Warranty5-Year Limited Warranty
Keys Provided2 restricted keys (additional available)
Available Configurations
Standard Yellow

High-visibility yellow with clear "ABORT STATION" marking

Corrosion-Resistant

Stainless steel construction for harsh environments

Weatherproof

IP65 rated for outdoor or wet location installations

Product Overview

The FW2732 Abort Station is a critical safety component for fire suppression systems, providing authorized personnel with the ability to prevent unnecessary system discharges. During the pre-discharge delay period (typically 30-60 seconds), trained personnel can use the abort station to stop the countdown and prevent agent release. This is essential for preventing costly false discharges, protecting expensive suppression agents, and avoiding downtime associated with system recharge. The key-operated design ensures only authorized personnel can access this critical function.

UL Listed & FM Approved

Certified to UL and FM standards for suppression system abort devices, ensuring reliable performance and compliance with international safety requirements.

Key-Operated Security

Restricted keyway prevents unauthorized access, ensuring only trained personnel can abort system discharge during pre-discharge delay periods.

Robust Construction

Built with industrial-grade materials and tamper-resistant features to withstand challenging environments and prevent unauthorized operation.

Compatible Suppression Systems
Clean Agent
FM-200, Novec 1230
For server rooms, archives, museums
CO₂ Systems
High/Low Pressure
For industrial and machinery spaces
Water Mist
Deluge Systems
For commercial and industrial use
Certifications & Compliance

UL Listed: Abort Switch Devices

NFPA 2001: Clean Agent Fire Extinguishing Systems

FM Approved: Factory Mutual Global

NFPA 12: Carbon Dioxide Extinguishing Systems

NFPA 750: Water Mist Fire Protection Systems

Local Codes: Meets most local fire code requirements

Product Features

Operation Features
  • Key-operated abort switch mechanism
  • Maintained contact switch (ON-OFF-ON)
  • Clear visual indication of abort status
  • Restricted keyway for security
  • Positive detent for switch positions
Operational Features
  • Dual LED indicators (Red/Green)
  • Weather-resistant keyway
  • Test function without system abort
  • Easy key replacement system
  • Tamper-evident design
Installation Features
  • Surface or flush mounting options
  • Quick-connect terminal block
  • Screw terminal connections
  • Pre-drilled mounting holes
  • Tamper-resistant fasteners included
Safety & Durability Features
  • IK08 impact resistance rating
  • Vandal-resistant construction
  • UV-stable materials for long life
  • Corrosion-resistant components
  • High-temperature resistant materials
Abort Station Importance: Abort stations are critical safety devices for fire suppression systems, providing authorized personnel with the ability to prevent unnecessary system discharges during the pre-discharge delay period. This delay (typically 30-60 seconds) allows time for personnel to investigate alarms and abort the discharge if it's a false alarm. The FW2732's key-operated design ensures only authorized, trained personnel can access this function, preventing accidental or unauthorized abort operations that could compromise safety.

Installation & Configuration

Installation Guidelines
  • Install per NFPA 2001 and local code requirements
  • Mount 60" above finished floor (accessible height)
  • Place near protected area entrances
  • Ensure clear visibility and accessibility
  • Install with "ABORT STATION" label facing outward
Wiring Requirements
Electrical Requirements

24VDC/120VAC system voltage, SPDT contact configuration.

Wiring Configuration

Standard three-wire connection for system integration. Clearly marked terminals.

Terminal Connections

Screw terminals accept 12-22 AWG wire. Quick-connect option available.

Installation Steps
  1. Verify power is off to suppression system
  2. Select mounting location per code requirements
  3. Mark and drill mounting holes using template
  4. Route control wiring to installation location
  5. Connect wires to terminal block (SPDT contact)
  6. Mount abort station to wall using provided hardware
  7. Test operation using key (verify LED indicators)
  8. Verify system integration with suppression controller
  9. Store keys in secure, accessible location
  10. Document installation for inspection records
Testing & Commissioning
Functional Test

Test switch operation, LED indicators, and system integration.

Commissioning

Document test results and key control procedures for system certification.

Applications & Compatibility

Compatible Systems
  • Clean agent suppression systems
  • CO₂ fire suppression systems
  • Water mist and deluge systems
  • Foam suppression systems
Ideal Applications
  • Data centers and server rooms
  • Telecommunication facilities
  • Industrial control rooms
  • Museums and archives
  • Power generation control rooms
Application Scenarios
Data Centers

Clean agent system abort control to prevent costly false discharges.

Industrial Facilities

CO₂ system abort for machinery fire protection during maintenance.

Cultural Heritage

Clean agent abort for museums and archives during false alarms.

Benefits

Code Compliance: Meets NFPA 2001 and UL requirements

Cost Savings: Prevents expensive false discharges

Authorized Control: Key-operated prevents unauthorized use

Asset Protection: Protects expensive suppression agents

Easy Maintenance: Simple testing and operation

Downtime Reduction: Prevents unnecessary system recharge

Maintenance Requirements
Visual Inspection

Monthly
Check for damage and LED operation

Functional Test

Quarterly
Test switch and system integration

Key Control Audit

Annual
Verify key security and access control