Single Action Station

FW2723 - Manual Fire Alarm Call Point

Push-Button • Simple Activation • UL Listed • Emergency Response

SIMPLE ACTIVATION
Waterproof cover
NFPA 72 Compliant
UL Listed NFPA 72 EN 54-11 CE Certified
Activation Force: 10-20 N (Push Button)

Single Action Station

FW2723

Push-Button
Simple Activation
Press for alarm initiation
UL Listed
Intelligent Circuit
Quality Tested
Easy Installation

The FW2723 Single Action Station is a reliable and intuitive manual fire alarm call point designed for straightforward emergency activation. Featuring a simple push-button mechanism with clear visual and tactile feedback, it provides reliable manual fire alarm initiation while minimizing accidental activations. Designed for public areas, corridors, and emergency egress routes, this device meets strict safety standards while offering durable, vandal-resistant construction.

Technical Datasheet

Download detailed specifications and installation guide

Request Quote

Get pricing and availability for your project

Contact Sales

Technical Specifications

Model NumberFW2723
Product NameSingle Action Station
Device TypeManual Fire Alarm Call Point
Activation MethodPush-Button Only
Activation Force10-20 Newtons (1.0-2.0 kg)
Actuation Travel4-6 mm with positive click feedback
CertificationsUL Listed, NFPA 72, EN 54-11, CE
ManufacturerMaple Armor / Tongfang BMS
System CompatibilityConventional & Addressable Systems
Contact ConfigurationSPST Normally Open (NO)
Contact Rating24VDC, 100mA maximum
Contact Resistance< 100 mΩ when closed
Activation IndicationRed LED, Physical Flag
Reset MethodKey-operated mechanical reset
Operating Temperature Range14°F to 120°F (-10°C to 49°C)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Relative Humidity10% to 95% RH (Non-condensing)
Impact ResistanceIK07 (Medium impact resistant)
Dimensions4.7" x 4.7" x 2.4" (120mm x 120mm x 60mm)
Weight12.3 oz (350 g)
ColorRed (Standard), with white lettering
MountingWall Mount, 48" AFF recommended
TerminalsScrew terminals, 12-22 AWG wire
IP RatingIP54 (Dust and splash resistant)
Warranty5-Year Limited Warranty
Available Configurations
Standard Red

High-visibility emergency red with white "FIRE" lettering

Corrosion-Resistant

Stainless steel finish for harsh environments

Weatherproof

IP65 rated for outdoor or wet location use

Product Overview

The FW2723 Single Action Station is an essential component of modern fire alarm systems, providing a simple yet effective method for manual alarm initiation. Designed for intuitive operation in emergency situations, it features a prominent red push-button that requires deliberate pressure to activate, preventing false alarms while ensuring reliable operation when needed. The single-action design focuses on simplicity and ease of use, making it suitable for public areas where quick recognition and operation are critical.

UL Listed

Certified to UL standards for Manual Fire Alarm Boxes, ensuring reliable performance and compliance with North American safety requirements.

Simple Push-Button Operation

Intuitive single-action design with clear tactile feedback and audible click confirmation upon activation.

Durable Construction

Built with impact-resistant materials and tamper-resistant features to withstand public use and environmental challenges.

Compatible Systems
Maple Armor
Native Compatibility
Optimized for Maple Armor control panels
Conventional
Zone Systems
Works with conventional fire alarm systems
Addressable
Smart Systems
Compatible with addressable fire alarm systems
Certifications & Compliance

UL Listed: Manual Fire Alarm Boxes

NFPA 72: National Fire Alarm Code

EN 54-11: European Standard

IBC: International Building Code

ADA: Accessible height and operation

Local Codes: Meets most local fire code requirements

Product Features

Activation Features
  • Simple push-button activation
  • Optimized activation force (10-20N)
  • Clear tactile feedback with positive click
  • Visual indication of activation status
  • Mechanical latching for sustained alarm signal
Operational Features
  • Key-operated reset mechanism
  • Integrated status LED indicator
  • Physical flag showing activation state
  • Audible click on activation
  • Test function without activation
Installation Features
  • Surface or semi-flush mounting
  • Quick-connect terminal block
  • Screw terminal connections
  • Pre-drilled mounting holes
  • Tamper-resistant fasteners included
Safety & Durability Features
  • IK07 impact resistance rating
  • Vandal-resistant construction
  • UV-stable materials for long life
  • Corrosion-resistant components
  • High-temperature resistant materials
Single Action Advantage: The FW2723's single-action push-button design offers simplicity and reliability. Unlike dual-action stations, it provides immediate operation without confusion, making it ideal for public spaces, schools, healthcare facilities, and other environments where quick, unambiguous operation is essential during emergencies. The optimized activation force prevents accidental triggers while ensuring deliberate activation when needed.

Installation & Configuration

Installation Guidelines
  • Install per NFPA 72 and local code requirements
  • Mount 48" above finished floor (ADA recommendation)
  • Place within 5 feet of exit doors
  • Ensure clear visibility and accessibility
  • Maximum 200 feet travel distance between units
Wiring Requirements
Electrical Requirements

24VDC system voltage, normally open contact configuration.

Wiring Configuration

Two-wire connection for conventional systems. Clearly marked terminals.

Terminal Connections

Screw terminals accept 12-22 AWG wire. Quick-connect option available.

Installation Steps
  1. Turn off power to fire alarm system
  2. Select mounting location per code requirements
  3. Mark and drill mounting holes using template
  4. Route wiring to installation location
  5. Connect wires to terminal block (NO contact)
  6. Mount call point to wall using provided hardware
  7. Test operation by pressing button
  8. Verify alarm signal at control panel
  9. Reset device using provided key
  10. Document installation for inspection records
Testing & Commissioning
Functional Test

Press button to verify contact closure and alarm initiation at panel.

Commissioning

Document test results and device location for certification.

Applications & Compatibility

Compatible Systems
  • Conventional fire alarm systems
  • Addressable fire alarm systems
  • Maple Armor control panels
  • Industry-standard monitoring systems
Ideal Applications
  • Building corridors and exit routes
  • Lobbies and reception areas
  • Educational institutions
  • Healthcare facilities
  • Commercial office buildings
Application Scenarios
Schools & Universities

Simple operation for students and staff in educational environments.

Healthcare Facilities

Reliable activation in hospitals, clinics, and care facilities.

Office Buildings

Positioned near exits and in high-traffic areas for quick access.

Benefits

Code Compliance: Meets NFPA 72 and UL requirements

Immediate Response: Simple manual alarm initiation

Simple Operation: Intuitive push-button design

Cost Effective: Reliable performance at competitive price

Easy Maintenance: Simple testing and maintenance

Life Safety: Critical component for occupant safety

Maintenance Requirements
Visual Inspection

Monthly
Check for damage or obstructions

Functional Test

Quarterly
Test push-button operation

Full Test

Annual
Complete operational test