Dual Action Station

FW2721 - Manual Fire Alarm Call Point

Break-Glass • Push-Button • Key-Operated • Emergency Activation

MANUAL ACTIVATION
NFPA 72 Compliant
UL 38 NFPA 72 EN 54-11 CE Certified
Activation Force: 15-30 N (Break Glass)

Dual Action Station

FW2721

Break-Glass
Emergency Activation
Visible emergency indication
Push-Button
Manual Activation
Press for alarm initiation
Key Reset
Authorized Reset
Secure system restoration
UL 38 Certified
Dual Activation
Quality Tested
Easy Installation

The FW2721 Dual Action Station is a high-visibility manual fire alarm call point designed for immediate emergency activation by building occupants. Featuring both break-glass and push-button activation methods, it provides reliable manual fire alarm initiation with clear visual indication of activation. Designed for high-traffic areas and emergency egress routes, this device meets strict safety standards while offering vandal-resistant construction.

Get Quote

Technical Specifications

Model NumberFW2721
Product NameDual Action Station
Device TypeManual Fire Alarm Call Point
Activation MethodsBreak-Glass & Push-Button
Activation Force (Break Glass)15-30 Newtons (1.5-3.0 kg)
Actuation Travel (Push-Button)3-5 mm with positive click
CertificationsUL 38, NFPA 72, EN 54-11
ManufacturerMaple Armor / Tongfang BMS
System CompatibilityConventional & Addressable Systems
Contact ConfigurationSPST Normally Open (NO)
Contact Rating24VDC, 100mA maximum
Contact Resistance< 100 mΩ when closed
Activation IndicationRed LED, Physical Flag, Broken Glass
Reset MethodKey-operated mechanical reset
Operating Temperature Range14°F to 120°F (-10°C to 49°C)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Relative Humidity10% to 95% RH (Non-condensing)
Impact ResistanceIK08 (High impact resistant)
Dimensions4.7" x 4.7" x 2.4" (120mm x 120mm x 60mm)
Weight14.1 oz (400 g)
ColorRed (Standard), with white lettering
MountingWall Mount, 48" AFF recommended
TerminalsScrew terminals, 12-22 AWG wire
IP RatingIP54 (Dust and splash resistant)
Warranty5-Year Limited Warranty
Glass ReplacementEasy-access replacement panes
Available Configurations
Standard Red

High-visibility emergency red

Stainless Steel

Corrosion-resistant finish

Vandal-Resistant

Heavy-duty construction

Product Overview

The FW2721 Dual Action Station is a critical component of any comprehensive fire alarm system, providing manual initiation capability for building occupants. Designed for intuitive operation in emergency situations, it combines immediate visual identification with reliable mechanical actuation. The dual-action design allows for either deliberate push-button activation or emergency break-glass operation, ensuring the device can be activated quickly and effectively regardless of the situation or user familiarity.

UL 38 Certified

Certified to UL Standard 38 for Manual Fire Alarm Boxes, ensuring reliable performance and compliance with North American safety standards.

Dual Activation Methods

Combines push-button convenience with break-glass emergency activation, providing flexibility for different emergency scenarios and user preferences.

Vandal-Resistant Design

Constructed with impact-resistant materials and tamper-resistant features to withstand challenging environments and prevent accidental activation.

Activation Technology
Push-Button Activation

Simple press operation with tactile feedback and positive click for immediate alarm initiation.

Break-Glass Emergency

Breakable glass panel for emergency situations, providing visible indication of activation.

Key-Operated Reset

Secure reset mechanism requiring authorized personnel to restore the device after activation.

Certifications & Compliance

UL 38: Standard for Manual Fire Alarm Boxes

NFPA 72: National Fire Alarm Code

EN 54-11: European Manual Call Point Standard

IBC: International Building Code

ADA: Americans with Disabilities Act compliant

Local Codes: Complies with most local fire codes

Product Features

Activation Features
  • Dual activation methods (push-button & break-glass)
  • Optimized activation force (15-30N for glass)
  • Tactile feedback with positive click action
  • Clear visual indication of activation status
  • Mechanical latching for sustained alarm signal
Operational Features
  • Key-operated reset mechanism
  • Easy glass replacement without tools
  • Integrated status LED indicator
  • Physical flag indicating activation
  • Audible click on activation
Installation Features
  • Surface or semi-flush mounting options
  • Quick-connect terminal block
  • Screw terminal connections
  • Pre-drilled mounting holes
  • Tamper-resistant fasteners
Safety & Durability Features
  • IK08 impact resistance rating
  • Vandal-resistant construction
  • UV-stable materials for outdoor use
  • Corrosion-resistant components
  • Shatter-resistant glass options
Manual Call Point Importance: Manual call points are essential components of any fire alarm system, providing building occupants with the ability to initiate an alarm when they discover a fire. Unlike automatic detectors, manual call points allow for immediate human response, which can be critical in situations where fires develop quickly or in areas not covered by automatic detection. The FW2721's dual-action design ensures it can be activated quickly and reliably by anyone, regardless of their familiarity with the device.

Installation & Configuration

Installation Guidelines
  • Install per NFPA 72 and local code requirements
  • Mount 48" above finished floor (ADA recommendation)
  • Place within 5 feet of exit doors
  • Ensure clear visibility and accessibility
  • Maximum 200 feet travel distance between units
Wiring Requirements
Electrical Requirements

24VDC system voltage, normally open contact.

Wiring Configuration

Two-wire connection for conventional systems.

Terminal Connections

Screw terminals accept 12-22 AWG wire. Clearly marked terminals.

Installation Steps
  1. Turn off power to fire alarm system
  2. Select mounting location per code requirements
  3. Mark and drill mounting holes
  4. Route wiring to installation location
  5. Connect wires to terminal block (NO contact)
  6. Mount call point to wall using provided hardware
  7. Test operation by activating push-button
  8. Verify alarm signal at control panel
  9. Reset device using provided key
  10. Install glass break element (if not pre-installed)
Testing & Commissioning
Push-Button Test

Press button to verify contact closure and alarm initiation.

Break-Glass Test

Test with break tool to verify emergency activation function.

Applications & Compatibility

Compatible Systems
  • Conventional fire alarm systems
  • Addressable fire alarm systems
  • Maple Armor control panels
  • Industry-standard monitoring systems
Ideal Applications
  • Building corridors and exit routes
  • Lobbies and reception areas
  • Industrial facilities and warehouses
  • Educational institutions
  • Healthcare facilities
Application Scenarios
Office Buildings

Positioned near exits and in high-traffic areas for quick access.

Industrial Facilities

Vandal-resistant models for challenging industrial environments.

Educational Facilities

High-visibility units for schools and university buildings.

Benefits

Code Compliance: Meets NFPA 72 and UL 38 requirements

Immediate Response: Allows manual alarm initiation

Dual Operation: Push-button and break-glass options

Cost Effective: Reliable performance at competitive price

Easy Maintenance: Simple testing and glass replacement

Life Safety: Critical component for occupant safety

Maintenance Requirements
Visual Inspection

Monthly
Check for damage or obstructions

Functional Test

Quarterly
Test push-button operation

Full Test

Annual
Complete break-glass test