Duct Smoke Detector

FW562 - UL Listed HVAC Fire Detection System

UL Listed • Intelligent Detection • HVAC Safety Compliance

HVAC SAFETY
UL Listed
UL Listed NFPA 90A Compliant CSFM Listed HVAC Certified
Airflow Range: 100-4,000 FPM

Duct Smoke Detector

FW562

UL Listed
Intelligent
Quality Tested
Easy Install

The FW562 Duct Smoke Detector is a UL listed smoke detection device designed specifically for HVAC duct systems. It provides early warning of smoke spreading through ventilation systems, helping to prevent smoke circulation throughout buildings during fire events. Ideal for commercial, institutional, and industrial applications.

Technical Specifications

Model NumberFW562
Product NameDuct Smoke Detector
Detection TypePhotoelectric Smoke Detection
Airflow Range100 to 4,000 FPM (0.5 to 20.3 m/s)
System CompatibilityConventional & Addressable Systems
CertificationUL Listed, CSFM, FM Approved
ManufacturerMaple Armor / Tongfang
Wiring Configuration2-Wire or 4-Wire Options
Operating Voltage12-30VDC
Standby Current50μA @ 24VDC
Alarm Current60mA @ 24VDC
Alarm IndicationRed LED, Remote LED Output
Test MethodMagnet Test, Remote Test Input
Operating Temperature Range32°F to 120°F (0°C to 49°C)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Relative Humidity10% to 95% RH (Non-condensing)
Duct Size Compatibility6" to 72" (152mm to 1829mm)
Sampling TubesIncluded (Adjustable length)
Dimensions (Controller)8.5" x 6.5" x 2.5" (216 x 165 x 64mm)
Weight2.2 lbs (1.0 kg)
ColorWhite (Standard)
MountingDuct-mounted with Sampling Tubes
IP RatingIP54 (Dust and splash resistant)
Warranty3-Year Limited Warranty
Available Configurations
Standard

Basic duct smoke detection

Intelligent

With sensitivity monitoring

Advanced

With airflow monitoring

Product Overview

The FW562 Duct Smoke Detector is a UL listed smoke detection device specifically engineered for HVAC duct systems. It provides early detection of smoke spreading through ventilation ducts, helping to prevent smoke circulation throughout buildings during fire events. Utilizing advanced photoelectric technology, it samples air from the duct and provides reliable detection even in challenging airflow conditions.

UL Listed

Meets rigorous UL standards for duct smoke detector performance and reliability.

Airflow Compensation

Automatic compensation for varying duct air velocities (100-4,000 FPM).

HVAC Optimized

Specifically designed for duct mounting and HVAC system integration.

Detection Technology
Air Sampling

Continuously samples air from HVAC ducts using precision sampling tubes.

Photoelectric Sensing

Advanced photoelectric chamber for reliable smoke particle detection.

Airflow Monitoring

Monitors and compensates for duct air velocity variations.

Certifications & Compliance

UL Listed: Standard for Duct Smoke Detectors

NFPA 90A: Standard for Air-Conditioning Systems

CSFM: California State Fire Marshal

FM Approved: Factory Mutual

IBC: International Building Code

Local Codes: Complies with most local mechanical codes

Product Features

Detection Features
  • Photoelectric smoke detection technology
  • Automatic airflow compensation (100-4,000 FPM)
  • Dual sampling tubes for accurate detection
  • Dust and dirt compensation algorithms
  • Sensitivity monitoring and reporting
Operational Features
  • Remote test capability
  • Built-in magnet test for easy maintenance
  • Dual alarm LEDs (local and remote)
  • Remote alarm relay output
  • Low power consumption
Installation Features
  • Adjustable sampling tubes (6" to 72" ducts)
  • Easy-access hinged cover
  • Screw terminal connections
  • Knockouts for conduit entry
  • Tamper-resistant construction
Safety & Reliability Features
  • Short-circuit protection
  • Reverse polarity protection
  • Surge and transient protection
  • Self-diagnostics
  • Fault monitoring capability
Duct Smoke Detector Advantage: Duct smoke detectors are essential for HVAC system fire safety. They detect smoke in air handling systems before it spreads throughout a building, allowing for early warning and automatic shutdown of HVAC equipment to prevent smoke circulation. Required by NFPA 90A in many commercial and institutional buildings.

Installation & Configuration

Supply Duct
Supply/return air ducts
Air Handler
Air handling units
Plenum
Return air plenums
Installation Guidelines
  • Install per NFPA 90A requirements
  • Mount on straight duct sections (min 5 duct diameters from bends)
  • Position sampling tubes perpendicular to airflow
  • Ensure proper tube length (protrude 1/3 into duct)
  • Provide access for testing and maintenance
Wiring Requirements
Power Requirements

12-30VDC, 50μA standby, 60mA alarm. Use fire-rated cable.

Wiring Options

2-wire (power/alarm) or 4-wire (power, alarm, relay, remote).

Terminal Connections

Screw terminals accept 12-22 AWG wire. Clearly marked terminals.

Installation Steps
  1. Turn off power to fire alarm and HVAC systems
  2. Select location per NFPA 90A requirements
  3. Cut mounting hole in duct (size per instructions)
  4. Install sampling tube mounting collars
  5. Mount detector controller adjacent to duct
  6. Connect sampling tubes to controller
  7. Connect wiring (power, alarm, relay if used)
  8. Restore power to systems
  9. Test detector using magnet or remote test
  10. Verify airflow and detection operation

Applications & Compatibility

Compatible Systems
  • Conventional fire alarm panels
  • Addressable fire alarm systems
  • Maple Armor fire alarm systems
  • Building automation systems (BAS)
Ideal Applications
  • Commercial office buildings
  • Hospitals and healthcare facilities
  • Hotels and hospitality
  • Educational institutions
  • Shopping malls and retail
Application Scenarios
Healthcare Facilities

Critical for smoke control in hospital HVAC systems.

Commercial Buildings

Required in large air handling systems per NFPA 90A.

Educational Facilities

Essential for smoke detection in school ventilation systems.

Benefits

Code Compliance: Meets NFPA 90A requirements

Early Detection: Detects smoke in ducts before room detectors

HVAC Integration: Interfaces with building automation

Damage Prevention: Prevents smoke damage to HVAC equipment

Easy Maintenance: Simple testing and cleaning

Life Safety: Protects occupants from smoke inhalation

Maintenance Requirements
Visual Inspection

Monthly
Check for damage or obstructions

Functional Test

Semi-Annual
Test using magnet or remote test

Cleaning

Annual
Clean sampling tubes and chamber